Product List


Open Matrix System(OMS)


Data & Fiber Optic Cables


Connecting Hardware


Real Time Patching System


Cabling Solutions


Fire Performance Standard
 
E-shop
FAQ
Download
Contact
 
 
Product Profile  
 
           
    S-FTP Cat5E 4Pairs, LSOH Grade ( IEC332-1 )    
Product name: cat5e cable
       
Keywords:
utp cat5e cable, ftp cat5e cables, s-ftp cat5e cables
outdoor utp cat5e,lsoh grade ,4 pairs cables
             
    Product Picture    
   
  utp cat5e cable  Outdoor S-FTP Cat5E 4Pairs ( Water Blocking / UV Resistant )  outdoor stp cat5e cable  UTP Cat5E 4Pairs, LSFROH Grade ( IEC332-1 & IEC332-3C )  cat5e utp cables  S-FTP Cat5E 4Pairs, LSFROH Grade ( IEC332-1 & IEC332-3C )
       
Product Introduction

Flame Retardant CAT5e CWB/SWB/SWA Armoured Data Cables

FTX-CAT5e U/UTP4P24 cwb/swb/swa
FTX-CAT5e f/UTP4P24 cwb/swb/swa
FTX-CAT5e sf/FTP4P24 cwb/swb/swa

Flame Retardant Data Cables

APPLICATION
Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice
and data installations up to 100 MHz. In addition, these cables can be offered with copper wire
braid armoured & flame retardant outer sheath, providing additional mechanically protection still
maintaining the flexibility of the cable.

STANDARDS
Basic design to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical
Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING
60V

CABLE CONSTRUCTION
Conductors: 24AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
cwb: copper Wire Braid
swb: Steel Wire Braid
swa: Steel Wire Armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting
LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)
Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape &
copper wire braid.

Physical AND THERMAL PROPERTIES
Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG

 

24

Nominal Conductor Diameter

mm

0.53

maximum DC Resistant@20°C

Ω/100m

9.38

maximum DCR Unbalance

%

5

maximum mutual Capacitance

pF/m

55.8

maximum Capacitance Unbalance

pF/100m

330

Characteristic Impedance@1-100mHz

Ω

100+/-15

maximum Propagation Delay Skew

ns/100m

45

Transmission Properties

FREQ
mHz

maximum
Attenuation dB/100m

minimum
NEXT
dB

minimum
PSNEXT
dB

minimum
ELFEXT
dB/100m

minimum
PSELFEXT
dB/100m

minimum
RL
dB

0.772

1.8

67.0

64.0

66.0

63.0

1

2.0

65.3

62.3

63.8

60.8

20.0

4

4.1

56.3

53.3

51.7

48.7

23.0

8

5.8

51.8

48.8

45.7

42.7

24.5

10

6.5

50.3

47.3

43.8

40.8

25.0

16

8.2

47.3

44.3

39.7

36.7

25.0

20

9.3

45.8

42.8

37.7

34.7

25.0

25

10.4

44.3

41.3

35.8

32.8

24.3

31.25

11.7

42.9

39.9

33.9

30.9

23.6

62.5

17.0

38.4

35.4

27.8

24.8

21.5

100

22.0

35.3

32.3

23.8

20.8

20.1

Cat5E SF/UTP

Cat5E SF/UTP

CONSTRUCTION PARAMETERS

Cable Code

Construction
No. of elements×No. of cores in element×Conductor diameter

Nominal Insulation Thickness

Nominal Inner Sheath Thickness

Nominal Outer Sheath Thickness

Nominal Overall Diameter

Nominal
Weight

 

mm

mm

mm

mm

mm

kg/km

caT5e U/UTP cWb

4×2×0.53

0.2

0.6

1.0

7.68

97

caT5e U/UTP sWb

4×2×0.53

0.2

0.6

1.0

7.68

93

caT5e U/UTP sWa

4×2×0.53

0.2

0.6

1.0

8.68

165

caT5e f/UTP cWb

4×2×0.53

0.2

0.6

1.0

8.28

116

caT5e f/UTP sWb

4×2×0.53

0.2

0.6

1.0

8.28

112

caT5e f/UTP sWa

4×2×0.53

0.2

0.6

1.0

9.28

192

caT5e sf/UTP cWb

4×2×0.53

0.2

0.6

1.0

8.76

123

caT5e sf/UTP sWb

4×2×0.53

0.2

0.6

1.0

8.76

119

caT5e sf/UTP sWa

4×2×0.53

0.2

0.6

1.0

9.76

216