Flame Retardant CAT5e CWB/SWB/SWA Armoured Data Cables

FTX-CAT5e U/UTP4P24 cwb/swb/swa
FTX-CAT5e f/UTP4P24 cwb/swb/swa
FTX-CAT5e sf/FTP4P24 cwb/swb/swa

Flame Retardant Data Cables

APPLICATION

Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice
and data installations up to 100 MHz. In addition, these cables can be offered with copper wire
braid armoured & flame retardant outer sheath, providing additional mechanically protection still
maintaining the flexibility of the cable.

STANDARDS

Basic design to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical
Wire Test)
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING

60V

CABLE CONSTRUCTION

Conductors: 24AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
cwb: copper Wire Braid
swb: Steel Wire Braid
swa: Steel Wire Armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting
LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)
Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape &
copper wire braid.

Physical AND THERMAL PROPERTIES

Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG 24
Nominal Conductor Diameter mm 0.53
maximum DC Resistant@20°C Ω/100m 9.38
maximum DCR Unbalance % 5
maximum mutual Capacitance pF/m 55.8
maximum Capacitance Unbalance pF/100m 330
Characteristic Impedance@1-100mHz Ω 100+/-15
maximum Propagation Delay Skew ns/100m 45

Transmission Properties

FREQ
mHz
maximum
Attenuation dB/100m
minimum
NEXT
dB
minimum
PSNEXT
dB
minimum
ELFEXT
dB/100m
minimum
PSELFEXT
dB/100m
minimum
RL
dB
0.772 1.8 67.0 64.0 66.0 63.0
1 2.0 65.3 62.3 63.8 60.8 20.0
4 4.1 56.3 53.3 51.7 48.7 23.0
8 5.8 51.8 48.8 45.7 42.7 24.5
10 6.5 50.3 47.3 43.8 40.8 25.0
16 8.2 47.3 44.3 39.7 36.7 25.0
20 9.3 45.8 42.8 37.7 34.7 25.0
25 10.4 44.3 41.3 35.8 32.8 24.3
31.25 11.7 42.9 39.9 33.9 30.9 23.6
62.5 17.0 38.4 35.4 27.8 24.8 21.5
100 22.0 35.3 32.3 23.8 20.8 20.1

Cat5E SF/UTP

Cat5E SF/UTP

CONSTRUCTION PARAMETERS
Cable Code Construction
No. of elements×No. of cores in element×Conductor diameter
Nominal Insulation Thickness Nominal Inner Sheath Thickness Nominal Outer Sheath Thickness Nominal Overall Diameter Nominal
Weight
mm mm mm mm mm kg/km
caT5e U/UTP cWb 4×2×0.53 0.2 0.6 1.0 7.68 97
caT5e U/UTP sWb 4×2×0.53 0.2 0.6 1.0 7.68 93
caT5e U/UTP sWa 4×2×0.53 0.2 0.6 1.0 8.68 165
caT5e f/UTP cWb 4×2×0.53 0.2 0.6 1.0 8.28 116
caT5e f/UTP sWb 4×2×0.53 0.2 0.6 1.0 8.28 112
caT5e f/UTP sWa 4×2×0.53 0.2 0.6 1.0 9.28 192
caT5e sf/UTP cWb 4×2×0.53 0.2 0.6 1.0 8.76 123
caT5e sf/UTP sWb 4×2×0.53 0.2 0.6 1.0 8.76 119
caT5e sf/UTP sWa 4×2×0.53 0.2 0.6 1.0 9.76 216