Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables

FTX-CAT6 U/UTP4P24 cwb/swb/swa
FTX-CAT6 F/UTP4P24 cwb/swb/swa
FTX-CAT6 SF/UTP4P24 cwb/swb/swa

Flame Retardant Data Cables'

APPLICATION

Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT,
100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper
wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically
protection still maintaining the flexibility of the cable.

STANDARDS

Basic design to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical
Wire Test)
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE
0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation
(Vertically-mounted bundled wires
& cable test)
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*
minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING

60V

CABLE CONSTRUCTION

Conductors: 23AWG solid bare copper.
Insulation: HDPE .
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
cwb: copper Wire Braid
swb: Steel Wire Braid
swa: Steel Wire Armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH
compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat6 F/UTP: These cables
have collective shielding of aluminium/Polyester tape with drain wire.
Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper
wire braid with drain wire.

Physical AND THERMAL PROPERTIES

Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG 23
Nominal Conductor Diameter mm 0.56/0.57
maximum DC Resistant@20°C Ω/100m 9.38
maximum DCR Unbalance % 3
maximum mutual Capacitance pF/m 5.8
maximum Capacitance Unbalance pF/100m 30
Characteristic Impedance@1-100mHz Ω 100+/-15
maximum Propagation Delay Skew ns/100m 18

Transmission Properties

FREQ
mHz
maximum
Attenuation dB/100m
minimum
NEXT
dB
minimum
PSNEXT
dB
minimum
ELFEXT
dB/100m
minimum
PSELFEXT
dB/100m
minimum
RL
dB
0.772 1.8 76.0 74. 70.0 67.0
1 2.0 74.3 72.3 67.8 64.8 20.0
4 3.8 65.3 63.3 55.7 52.7 23.0
8 5.3 60.8 58.8 49.7 46.7 24.5
10 6.0 59.3 57.3 47.8 44.8 25.0
16 7.6 56.3 54.3 43.7 40.7 25.0
20 8.5 54.8 52.8 41.7 38.7 25.0
25 9.5 53.3 51.3 39.8 36.8 24.3
31.25 10.7 51.9 49.9 37.9 34.9 23.6
62.5 15.4 47.4 45.4 31.8 28.8 21.5
100 19.8 44.3 42.3 27.8 24.8 20.1
155 25.2 41.5 39.5 23.9 20.9 18.8
200 29.0 39.8 37.8 21.7 18.7 18.0
250 32.8 38.3 36.3 19.8 16.8 17.3

Cat6 SF/UTP

Cat6 SF/UTP

CONSTRUCTION PARAMETERS

Cable Code Construction
No. of elements×No. of cores in element×Conductor diameter
Nominal Insulation Thickness Nominal Inner Sheath Thickness Nominal Outer Sheath Thickness Nominal Overall Diameter Nominal
Weight
mm mm mm mm mm kg/km
caT6 U/UTP cWb 4×2×0.58 0.2 0.6 1.0 7.88 115
caT6 U/UTP sWb 4×2×0.58 0.2 0.6 1.0 7.88 109
caT6 U/UTP sWa 4×2×0.53 0.2 0.6 1.0 8.88 189
caT6 f/UTP cWb 4×2×0.58 0.2 0.6 1.0 8.48 126
caT6 f/UTP sWb 4×2×0.58 0.2 0.6 1.0 8.48 132
caT6 f/UTP sWa 4×2×0.58 0.2 0.6 1.0 9.48 213
caT6 sf/UTP cWb 4×2×0.58 0.2 0.6 1.0 8.96 154
caT6 sf/UTP sWb 4×2×0.58 0.2 0.6 1.0 8.96 148
caT6 sf/UTP sWa 4×2×0.58 0.2 0.6 1.0 9.96 242